This is an old revision of the document!
The following documentation is for the DIN-RYx-N devices CFLink protocol messages.
The TRLYSET
(Send) command is used to send a command to the relay channels.
> [F2]<ID>[F3]TRLYSET[F4]<PORT>:<STATE>[F5][F5]
P01-P08
.0
would set the relay to open, 1
would set the relay to close, T
would set the relay to toggle.
// The reply does not echo the data sent in an effort to reduce bus traffic < [F2]<ID>[F3]RIRBSND[F4][F5][F5]If sending multiple IR commands via a single CFLink message, the reply will only happen after all IR commands have been sent.
The RCV
(Receive) notification is generated when either the on-board IR receiver, or the external IR receiver detects an IR signal.
< [F2]<ID>[F3]RIRBRCV[F4]<PORT>:<IR_DATA>[F5][F5]
P01
= On-board Blaster outputP02
= Secondary emitter output
// IR Data is received via the on-board IR receiver, IR Blaster on CFLink ID [06] < [F2][06][F3]RIRBRCV[F4]P01:0066016100160119001601320016011A0016011900160132001601310016011A0016[F5][F5]