MOD-COM4
The MOD-COM4 is a modular unit capable of up to 4 x RS232 ports, also configurable for RS422 and RS485.
Ports
Front of the module has two 6-pin connectors, the top row and bottom row.
Each row can be configured as either:
- 2 x RS232 without flow control
- 1 x RS232 with flow control
- 1 x RS485 half-duplex
- 1 x RS485/422 full-duplex
Note that when using any RS232 mode in combination with RS485 or RS422 (any duplex type), the RS232 must be on ports 3 and/or 4 (bottom row).
RS232 can never be in ports 1 or 2 (top row) when using alongside RS485 or RS422 (bottom row).
For more details on the MOD-COM4 port configuration options, please see the MOD-COM4 CFLink documentation.
Front Pinouts
Pinouts for the various modes each connector can be configured to are as follows:
2 x RS232 without flow control
- TX-1
- Ground
- RX-1
- TX-2
- Ground
- RX-2
1 x RS232 with flow control
- TX
- Ground
- RX
- RTS
- Ground
- CTS
1 x RS485 half-duplex
- Data +
- Ground
- Not Connected
- Data -
- Ground
- Not Connected
1 x RS485/422 full-duplex
- TX +
- Ground
- RX +
- TX -
- Ground
- RX -
Rear Connector
The rear of every module contains a module port, used to connect the module into the modular controller base unit (DIN-MOD4, etc).
The pinout for this port is not published (as it has no benefit to any user).