• skip to content

CommandFusion Wiki

Documentation Resources

User Tools

  • Login

Site Tools

  • Recent changes
  • Media Manager
  • Sitemap
Trace:

relay

Search

You can find the results of your search below. If you didn't find what you were looking for, you can create or edit the page named after your query with the appropriate tool.

Results

Matching pagenames:

  • Relay Ports CFLink Protocol
  • Relay Tab
Relay Ports CFLink Protocol: 54 Hits
====== Relay Ports CFLink Protocol ====== The following documentation describes the CFLink protocol for controlling relay ports on any device with relays.\\ This includes relay modules, cards and standalon... A>[F5][F5] </sxh> * **<RELAYDATA>** = For each relay port in the module/device, the port status is returned in ''P##:<STATE>'' format. Multiple relay ports are included in a single reply using the Port
Relay Tab: 14 Hits
====== Relay Tab ====== {{:hardware:cf-mini:cf-mini-configuration:cf_mini_relay_tab.png?nolink|}} ===== 1 - Relay Port Settings ===== This is where you set the power on state for each of the relays in you... Mini. The options available are: * Open - the relay circuit will be open on power on * Closed - The relay circuit will be closed on power on * Latch - the relay will resume the last state on power
DIN-RY CFLink Protocol: 13 Hits
CFXSPW[F4]<PORT>:<DATA>[F5][F5] </sxh> ===== Relay Commands ===== ==== On / Off / Toggle ==== The ... ' (Send) command is used to send a command to the relay channels. === Data === <sxh cflink; light: true... ORT>:<STATE>[F5][F5] </sxh> * **<PORT>** = The relay channel (port) to be controlled. Relay channels w... * **<STATE>** = The command to set the status of relay. ''0'' would set the relay to open, ''1'' would s
MOD-SSRY4 Configuration: 12 Hits
====== MOD-SSRY4 Configuration ====== ===== 1 - Relay Port Settings ===== This is where you set the power... SSRY4. The options available are: * Open - the relay circuit will be open on power on * Closed - The relay circuit will be closed on power on * Latch - the relay will resume the last state on power ... ting ===== Use this section to manually test each relay on the CF Mini. The image shows the current relay
MOD-RY4 Configuration: 12 Hits
ules:mod-ry4:mod-ry4_tab.png?nolink|}} ===== 1 - Relay Port Settings ===== This is where you set the pow... D-RY4. The options available are: * Open - the relay circuit will be open on power on * Closed - The relay circuit will be closed on power on * Latch - the relay will resume the last state on power ... ting ===== Use this section to manually test each relay on the CF Mini. The image shows the current relay
MOD-HRY2 Configuration: 12 Hits
es:mod-hry2:mod-hry2_tab.png?nolink|}} ===== 1 - Relay Port Settings ===== This is where you set the pow... -HRY2. The options available are: * Open - the relay circuit will be open on power on * Closed - The relay circuit will be closed on power on * Latch - the relay will resume the last state on power ... ting ===== Use this section to manually test each relay on the CF Mini. The image shows the current relay
MOD-LRY8 Configuration: 12 Hits
es:mod-lry8:mod-lry8_tab.png?nolink|}} ===== 1 - Relay Port Settings ===== This is where you set the pow... -LRY8. The options available are: * Open - the relay circuit will be open on power on * Closed - The relay circuit will be closed on power on * Latch - the relay will resume the last state on power ... ting ===== Use this section to manually test each relay on the CF Mini. The image shows the current relay
Input/Output (IO) CFLink Protocol: 7 Hits
'1'' for video sensed. * ''E'' = ''E''xternal relay control output, 0-24V DC (external power supply r... t 4 = Voltage, 12.5V reading // Port 5 = External relay control, Off // Port 6 = LED ouput, On // Port 7 ... oltage, 1.2 V minimum change // Port 5 = External relay control, Power On State = Off // Port 6 = LED oup... oltage, 1.2 V minimum change // Port 5 = External relay control, Power On State = Off // Port 6 = LED oup
CFLink Protocol Introduction: 7 Hits
ll the device to perform an action, such as set a relay state or send data out a serial port.\\ \\ A tran... k; light: true> // Port Separator example - Close relay port 1, open relay port 2 on a CF Mini on CFLink ... ort Separator example, with module number - Close relay port 1, open relay port 2 on Module 2 of a MOD4 o... ue> // Module Separator example - Module 1, Close relay ports 1 and 2, Module 2, Open relay ports 1 and 2
DIN-RY8-N: 7 Hits
Y8-N ====== The DIN-RY8-N is a 8-channel compact relay controller with load detection feature. In addition to the relay controls, RS485/RS232 looping/external control bus for connecting multiple units or ... the load first before deciding whether or not the relay needs to be switched. ===== Macros/Rules ===== ... idge or Solo products. ===== Connectivity ===== Relay Outputs - 8 x latching relay switching outputs; 8
Global Cache: 7 Hits
is used for such things as iTach status, IR data, relay operation, and reading digital input states. eria... or is assigned an IP Port starting at 4999. ==== Relay Commands ==== Relay commands send to Global Cache... are must be in a specific format as shown below. Relay state is set as follows:\\ setstate,1:1,<outputstate>\x0D for the 1st relay output\\ setstate,1:2,<outputstate>\x0D for the 2nd relay output\\ setsta
DIN-RY5-N: 7 Hits
Y5-N ====== The DIN-RY5-N is a 5-channel compact relay controller with load detection feature, the smaller version of the DIN-RY8-N. In addition to the relay controls, RS485/RS232 looping/external control bu... the load first before deciding whether or not the relay needs to be switched. ===== Macros/Rules ===== ... idge or Solo products. ===== Connectivity ===== Relay Outputs - 5 x latching relay switching outputs; 5
DIN-RY Config Tool: 7 Hits
ware tool designed specifically for the DIN-RYx-N relay controller series. Among the features of this too... status, firmware update, general device settings, relay interlocks, setting different dry contact modes, ... ll the general information and port status of the relay, load and dry contact on the device. It also show... re also available here for testing the individual relay channels. ==== General Settings ==== You can chan
Quick Start Guide Page 3 - System Commander: 6 Hits
an event like a dry contact closing can trigger a relay to close and send a specific IR command.\\ {{ :so... lower the projector screen. This is done using a relay connected to a CF Mini.\\ Click on ''Add Action'', then ''Action Builder''. Choose ''Relay'' as the action type, and make sure the target device is ... CF Mini you are programming your macro on.\\ The relay ports will automatically populate based on the po
CF Mini: 5 Hits
Error Codes: 4 Hits
Quick Start Guide Page 4 - System Commander: 4 Hits
Getting Started: 4 Hits
DIN-MOD4: 3 Hits
MOD4: 3 Hits
Hardware: 3 Hits
MOD4/DIN-MOD4 CFLink Protocol: 3 Hits
Slots Tab: 3 Hits
LAN Bridge CFLink Protocol: 3 Hits
CF Mini CFLink Protocol: 3 Hits
Control4 Integration: 3 Hits
Quick Start Guide Page 2 - System Commander: 2 Hits
MOD-LRY8: 2 Hits
MOD-SSRY4: 2 Hits
MOD-HRY2: 2 Hits
MOD-RY4: 2 Hits
Common Device Protocol: 2 Hits
CARD-LRY3: 2 Hits
CFLink Protocol: 2 Hits
System Commander Release Notes: 1 Hits
Notification Targets: 1 Hits
Target Notification Tab: 1 Hits
Software: 1 Hits
MOD-IO8 Configuration: 1 Hits
CFLink Command Builder: 1 Hits
I/O Tab: 1 Hits
MOD-IO8: 1 Hits

Page Tools

  • Show pagesource
  • Old revisions
  • Backlinks
  • Back to top
  • Export PDF
Donate Powered by PHP Valid HTML5 Valid CSS Driven by DokuWiki