CommandFusion Wiki

Documentation Resources

User Tools

Site Tools


hardware:cflink:irblaster-cflink-protocol

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

hardware:cflink:irblaster-cflink-protocol [2012/08/22 06:00]
aaron
hardware:cflink:irblaster-cflink-protocol [2012/10/18 02:43] (current)
jarrod [SND - Send IR]
Line 1: Line 1:
-====== ​IRBlaster ​CFLink Protocol ======+====== ​IR Blaster ​CFLink Protocol ======
  
-The following documentation is for the IRBlaster ​device CFLink protocol messages.+The following documentation is for the IR Blaster ​device CFLink protocol messages.
  
 ===== Transmission Messages ===== ===== Transmission Messages =====
Line 7: Line 7:
 ==== SND - Send IR ==== ==== SND - Send IR ====
  
-The ''​SND''​ (Send) command is used to send an IR command via one or more IR ports on the IRBlaster.+The ''​SND''​ (Send) command is used to send an IR command via one or more IR ports on the IR Blaster.
  
 === Data === === Data ===
Line 15: Line 15:
 </​sxh>​ </​sxh>​
  
-  * **<​PORT>​** = The IR port to send the IR data from. 3 chars, uppercase '​P'​ followed by the port number (2 digits)+  * **<​PORT>​** = The IR port to send the IR data from. 3 chars, uppercase ​''P'' followed by the port number (2 digits)
     *''​P01''​ = On-board Blaster output     *''​P01''​ = On-board Blaster output
     *''​P02''​ = Secondary emitter output     *''​P02''​ = Secondary emitter output
Line 49: Line 49:
 <sxh cflink; light: true> <sxh cflink; light: true>
 // Send a CCF hex code via the Blaster output. Send a database IR code to the secondary emitter output.  ​ // Send a CCF hex code via the Blaster output. Send a database IR code to the secondary emitter output.  ​
-// From IRBlaster ​on CFLink ID [06].+// From IR Blaster ​on CFLink ID [06].
 > [F2][06][F3]TIRBSND[F4]P01:​RAW:​0000 0067 0000 0015 0060 0018 0030 0018 0018 0018 0030 0018 0018 0018 0030 0018 0018 0018 0018 0018 0018 0018 0030 0018 0018 0018 0030 0018 0030 0018 0030 0018 0018 0018 0018 0018 0030 0018 0018 0018 0018 0018 0030 0018 0018 0216|P02:​DBA:​06:​1033:​01[F5][F5] > [F2][06][F3]TIRBSND[F4]P01:​RAW:​0000 0067 0000 0015 0060 0018 0030 0018 0018 0018 0030 0018 0018 0018 0030 0018 0018 0018 0018 0018 0018 0018 0030 0018 0018 0018 0030 0018 0030 0018 0030 0018 0018 0018 0018 0018 0030 0018 0018 0018 0018 0018 0030 0018 0018 0216|P02:​DBA:​06:​1033:​01[F5][F5]
 // Reply // Reply
Line 84: Line 84:
  
 <sxh cflink; light: true> <sxh cflink; light: true>
-// IR Data is received via the on-board IR receiver, ​IRBlaster ​on CFLink ID [06]+// IR Data is received via the on-board IR receiver, ​IR Blaster ​on CFLink ID [06]
 < [F2][06][F3]RIRBRCV[F4]P01:​0066016100160119001601320016011A0016011900160132001601310016011A0016[F5][F5] < [F2][06][F3]RIRBRCV[F4]P01:​0066016100160119001601320016011A0016011900160132001601310016011A0016[F5][F5]
 </​sxh>​ </​sxh>​
hardware/cflink/irblaster-cflink-protocol.1345615224.txt.gz ยท Last modified: 2012/08/22 06:00 by aaron