• skip to content

CommandFusion Wiki

Documentation Resources

User Tools

  • Login

Site Tools

  • Recent changes
  • Media Manager
  • Sitemap
Trace:

rs232
The page (rs232) doesn't exist. You have been redirected automatically to the search engine.
This message was fired by 404Manager Plugin.

Search

You can find the results of your search below. If you didn't find what you were looking for, you can create or edit the page named after your query with the appropriate tool.

Results

Matching pagenames:

  • On-Board RS232 Port Protocol
COM Module/Card CFLink Documentation: 37 Hits
COM4 supports up to 4 COM port combinations, with RS232, RS422 and RS485 support, including flow control ... tions.\\ \\ The default port configuration is 4 x RS232, 9600 Baud Rate, 8 Data Bits, No Parity, 1 Stop B... e COM4 module:\\ <html> <style type="text/css"> .rs232, .rs232H, .rs485, .rs422 { background-color: #fc... ss="tableheading">Legend:</td> <tr> <td class="rs232">RS232 without handshaking/flow control</td> <t
On-Board RS232 Port Protocol: 28 Hits
====== On-Board RS232 Port Protocol ====== This document defines the CFLink protocol for working with th... The ''SPC'' query requests the current on-board RS232 port settings of a device. === Data === The ''S... required if the device has more than one on-board RS232 port, such as the [[hardware:solo|Solo]]. * **<MODE>** = The mode of the RS232 port: * ''OFF'' (Disabled) means the serial port is turned off,
Solo: 18 Hits
l-in-one control system.\\ On-board ports include RS232 (with flow control), IR (which also operate as 1-way RS232 transmission ports), IR Blaster on 3 sides, dry contact inputs and Ethernet.\\ The Solo fe... al detected * Off = No IR signal detected * RS232 Activity (blue, numbered 1 and 2) * Flashing = RS232 data being sent or received via the associated on-board RS232 port. * Off = No RS232 dat
LAN Bridge: 16 Hits
== The CommandFusion LAN Bridge is the Ethernet & RS232 gateway to the CFLink bus. \\ Place one LAN Bridg... device within that CFLink network via Ethernet or RS232. The LAN Bridge features an on-board real time c... Port Program Mode (Amber) * Solid = On-board RS232 port is in Program Mode (for communicating with CFLink devices via RS232). * COM Port RS232 Mode * Solid = On-board RS232 port is in RS232 Mode
CF Mini: 15 Hits
8 x IR * 4 x I/O * 4 x 30V DC Relays * 1 x RS232/Program * 1 x CFLink * 1 x MicroSD Slot ====... Port Program Mode (Amber) * Solid = On-board RS232 port is in Program Mode (for communicating with CFLink devices via RS232). * COM Port RS232 Mode * Solid = On-board RS232 port is in RS232 Mode (for controlling third part RS232 devices). * Status (Amber) * The status LED can be configu
DIN-MOD4: 14 Hits
Or perhaps 4 COM4 modules, giving a maximum of 17 RS232 ports (including the on-board RS232 port).\\ ===... Port Program Mode (Amber) * Solid = On-board RS232 port is in Program Mode (for communicating with CFLink devices via RS232). * COM Port RS232 Mode * Solid = On-board RS232 port is in RS232 Mode (for controlling third part RS232 devices). ==== Pinhole Buttons ==== * Setup * Press to be
MOD4: 14 Hits
Or perhaps 4 COM4 modules, giving a maximum of 17 RS232 ports (including the on-board RS232 port).\\ ===... Port Program Mode (Amber) * Solid = On-board RS232 port is in Program Mode (for communicating with CFLink devices via RS232). * COM Port RS232 Mode * Solid = On-board RS232 port is in RS232 Mode (for controlling third part RS232 devices). ==== Pinhole Buttons ==== * Setup * Press to be
Solo CFLink Protocol: 13 Hits
above, targeting ''P07'' (Port 7). The Solo has RS232 ports, for which documentation is available in the [[on-board-rs232-port-protocol|On-Board RS232 docs]]. ===== Queries ===== ==== WHO - Device disc... input port names * ''COM'' = Query the on-board RS232 port names * ''IRX'' = Query the on-board IR po... 3|P04:DRY 4[F5][F5] // Request the names for the RS232 ports in the Solo at CFLink ID [03] > [F2][03][F3
LAN Bridge CFLink Protocol: 13 Hits
l messages.\\ The LAN Bridge also has an on-board RS232 port, for which documentation is available in the [[on-board-rs232-port-protocol|On-Board RS232 docs]]. ===== Common Definitions ===== The followin... ge: * ''1'' = CFLink slot * ''2'' = On-board RS232 slot * ''3'' = UDP Broadcasting slot (not avail... or ''1''). * **<RS232MODE>** = The mode of the RS232 port (''PGM'' or ''232''). * **<BAUD>** = The b
System Commander Quick Start Guide: 8 Hits
andFusion LAN Bridge. \\ \\ The second way is via RS232, this can be done with any CommandFusion device that has an on-board RS232 port.\\ {{ :software:system-commander:automatic_discovery_mode.png?direct&... Go Online''. Or using the F12 shortcut key. ==== RS232 Discovery ==== If we want to use the RS232 disco... ece of hardware you are using. Now we connect the RS232 port on the device to the COM port on your comput
CARD-COM4: 8 Hits
====== CARD-COM4 ====== This card adds additional RS232 and RS422/485 connectivity to the [[hardware:solo... \ Each row can be configured as either:\\ * 2 x RS232 without flow control * 1 x RS232 with flow cont... x RS485/422 full-duplex Note that when using any RS232 mode in combination with RS485 or RS422 (any duplex type), the RS232 must be on ports 3 and/or 4 (bottom row).\\ RS232 can never be in ports 1 or 2 (
DIN-RY5-N: 8 Hits
N-RY8-N. In addition to the relay controls, RS485/RS232 looping/external control bus for connecting multi... ntrol multiple DIN-RY family units in the looping RS232 or RS485 chain or to send custom messages to control systems via the RS232 and RS485 ports. Programming is completed using a cross-platform (Windows & Mac) application, connected via either RS232, RS485, USB or Ethernet when using an Ethernet to ser
DIN-RY8-N: 8 Hits
feature. In addition to the relay controls, RS485/RS232 looping/external control bus for connecting multi... ntrol multiple DIN-RY family units in the looping RS232 or RS485 chain or to send custom messages to control systems via the RS232 and RS485 ports. Programming is completed using a cross-platform (Windows & Mac) application, connected via either RS232, RS485, USB or Ethernet when using an Ethernet to ser
MOD-COM4: 8 Hits
e MOD-COM4 is a modular unit capable of up to 4 x RS232 ports, also configurable for RS422 and RS485.\\ ... \ Each row can be configured as either:\\ * 2 x RS232 without flow control * 1 x RS232 with flow cont... x RS485/422 full-duplex Note that when using any RS232 mode in combination with RS485 or RS422 (any duplex type), the RS232 must be on ports 3 and/or 4 (bottom row).\\ RS232 can never be in ports 1 or 2 (
Device Discovery: 8 Hits
IR Port CFLink Protocol: 7 Hits
General Tab: 5 Hits
Hardware: 5 Hits
General Tab: 5 Hits
Quick Start Guide Page 3 - System Commander: 5 Hits
Control4 Integration: 5 Hits
Clipsal CBus Plugin: 4 Hits
General Tab: 4 Hits
DIN-RY CFLink Protocol: 4 Hits
Getting Started: 3 Hits
CF Mini CFLink Protocol: 3 Hits
MOD4/DIN-MOD4 CFLink Protocol: 3 Hits
Quick Start Guide Page 4 - System Commander: 3 Hits
CFLink Protocol Introduction: 2 Hits
Quasar Electronics RGB Controller: 2 Hits
Residential iPad User Interface System: 2 Hits
Quick Start Guide - guiDesigner & iViewer: 2 Hits
DIN-RY Config Tool: 2 Hits
Error Codes: 2 Hits
CFLink Protocol: 2 Hits
Firmware Update Guide: 2 Hits
Interfacing with CFLink: 2 Hits
MOD-COM4 Configuration: 1 Hits
Global Cache: 1 Hits
Home Theater For Use By Elderly Person: 1 Hits
Serial Communications 101: 1 Hits
Quick Start Guide Page 2 - System Commander: 1 Hits

Page Tools

  • Show pagesource
  • Old revisions
  • Backlinks
  • Back to top
  • Export PDF
Donate Powered by PHP Valid HTML5 Valid CSS Driven by DokuWiki