====== MOD-HRY2 Configuration ====== {{:hardware:modules:mod-hry2:mod-hry2_tab.png?nolink|}} ===== 1 - Relay Port Settings ===== This is where you set the power on state for each of the relays in your MOD-HRY2. The options available are: * Open - the relay circuit will be open on power on * Closed - The relay circuit will be closed on power on * Latch - the relay will resume the last state on power on The ''Refresh'' button will request the settings from the device and display them in System Commander. You will lose any unsaved settings when you click this button. The ''Save'' Button will save any settings you have entered in System Commander to the device. ===== 2 - Port Testing ===== Use this section to manually test each relay on the CF Mini. The image shows the current relay state as per below image. {{:hardware:cf-mini:cf-mini-configuration:relay_testing.png?nolink|}} The buttons allow you change the state in real time of each relay. * Clicking the ''Open'' button will change the relay state to open * Clicking the ''Close'' button will change the relay state to close * Clicking the ''Toggle'' button will toggle the relay between open and close * Clicking the ''Pulse'' button will pulse the relay for the amount of time set in the ''Pulse (s)'' box. The measurement is in seconds.