====== CARD-COM4 ====== This card adds additional RS232 and RS422/485 connectivity to the [[hardware:solo|Solo controller]].\\ It features 2-4 configurable serial ports, exactly the same as the [[hardware:modules:mod-com4|MOD-COM4]] product.\\ ===== Ports ===== The card has two 6-pin connectors, the top row and bottom row.\\ Each row can be configured as either:\\ * 2 x RS232 without flow control * 1 x RS232 with flow control * 1 x RS485 half-duplex * 1 x RS485/422 full-duplex Note that when using any RS232 mode in combination with RS485 or RS422 (any duplex type), the RS232 must be on ports 3 and/or 4 (bottom row).\\ RS232 can never be in ports 1 or 2 (top row) when using alongside RS485 or RS422 (bottom row).\\ \\ For more details on the configuration options, please see the [[hardware:cflink:com-module-cflink-documentation|MOD-COM4 CFLink documentation]] which is the same for the CARD-COM4.\\ ==== Pinouts ==== Pinouts for the various modes each connector can be configured to are as follows:\\ {{:hardware:modules:com4-pinout.svg|}} **2 x RS232 without flow control** - TX-1 - Ground - RX-1 - TX-2 - Ground - RX-2 **1 x RS232 with flow control** - TX - Ground - RX - RTS - Ground - CTS **1 x RS485 half-duplex** - Data + (B) - Ground - Not Connected - Data - (A) - Ground - Not Connected **1 x RS485/422 full-duplex** - TX + - Ground - RX + - TX - - Ground - RX -